Astm c 1107 download free

Illinois modified astm c 1107 c 1107m17 effective date. Mixer for grout performance qualifications shall be clean, prewetted, and drained and essentially free of hardened mortar and other foreign material that can be removed with a trowel or by reasonably striking with a hammer. Astm c1107 standard specification for packaged dry. Find submittalready datasheets, sds, specs, icces reports. Astm c1107 c1107m standard specification for packaged dry, hydrauliccement grout nonshrink active standard astm c1107 c1107m developed by subcommittee. Astm c1107 standard specification for packaged dry, hydraulic. Last previous edition approved in 2010 as c107710a. Mortar this document comes with our free notification service, good for the life of the document. Surfaces to receive the grout must be free of any type of foreign material. Fastset nonshrink grout has a working time of about 30 minutes which allows plenty of time for placement. Grades a,b and c are no longer specified within the standard.

Last previous edition approved in 2002 as c 1107 02. Submittal data sc multipurpose grout nonshrink, non. Temperature grout temperature should be maintained at 50 90 degrees f 10 32 degrees c for best results. Submittal data sc multipurpose grout nonshrink, nonmetallic, multipurpose grout astm c1107 crd buildsite. Omni block concrete masonry units cmu have significantly passed the industry standard astm c9014 and c140 for structural block every time when manufactured and tested in the usa. Astm c1107 c1107m07, standard specification for packaged dry, hydrauliccement grout nonshrink, astm international, west conshohocken. Astm c1107c1107m standard specification for packaged. Pdf dimensional stability of grouttype materials used as. This test method covers measurement of the changes in height of hydrauliccement grout by the use of 75 by 150mm 3 by 6in. C 33 specification for concrete aggregates c 51 terminology relating to lime and limestone as used by the industry c lo9c 109m test method for compressive strength of hydraulic cement mortarsusing 2in. The pdf download is licensed per individual in which the individual can place on up to four electronic devices for their personal use. Masterflow 885 highprecision, nonshrink metallic aggregate grout with extended working time formerly.

Astm c1107c1107m14 standard specification for packaged dry, hydrauliccement grout nonshrink2014 astm on. In 2005, astm c 1107 was revised to where specific grades of nonshrink grout. In 2005, astm c 1107 was revised to where specific grades of nonshrink grout grades a,b and c are no longer specified within the standard. Issued 191015 in its yearbook complete editions issued in 1916, and triennially, 191836, inclusive. Bureau of materials packaged dry, hydrauliccement grout. This specification covers packaged dry, hydraulic cement grout nonshrink intended for use under applied load such as to support a structure, a machine, and the like where a change in height below initial placement height is to be avoided. To achieve specified performance in accordance with astm c1107, maintain temperature as close to 70 degrees f 21 degrees c as possible. The materials used as ingredients in packaged, dry, grout include hydraulic cement, fine aggregate, and other ingredients. A professionals handbook on grouting and concrete repair. Prospec c1107 construction grout is a nonshrink mixture of hydraulic cement, aggregate and additives.

For annual book of astm standards volume information, refer to the standards document summary page on the astm website. A professionals guide on grouting and concrete repair 3. Advantages uses ultrahigh 1, 7, and 28 day compressive strengths 95% eba is typically achieved following proper grouting procedures. There are probably at least 100 different cmu units available. For structural grouting and general purpose structural grouting. Downloaded from by federal highway administration on. Astm c140 standard test methods for sampling and testing. International masonry institute the national training center 17101 science drive bowie, md 20715 phone 301. Astm c1107 pdf 30 products find astm c products and abstract using the buildsite database. Its special formula also gives the user extremely high strength. Illinois modified astm c 1107c 1107m17 effective date. Astm c 1107c 1107m08 standard specification for packaged. This test method covers the determination of the compressive strength of hydraulic cement grout for preplacedaggregate pa concrete.

October 5, 2018 standard method of test for packaged dry, hydrauliccement grout nonshrink modifications apply only when testing material according to article 1024. Astm b16b16m10 freecutting brass rod, bar and shapes for use in. A professionals guide on grouting and concrete repair. This test result had the block at 3740 psi compressive strength when the minimum is only 2000 psi. E57 3d imaging format reference implementation of the astm 3d imaging format. Standard specification for packaged dry, hydrauliccement.

Astm c1107 c1107m standard specification for packaged dry, hydrauliccement grout nonshrink. I am not sure if the suggestions here were based on hypothetical or real sea. It is ideally suited for grouting machines or plates requiring optimum toughness and precision loadbearing support, including machine bases subject to thermal. This test method covers the determination of flow of hydraulic cement mortars.

Astm c1107 pdf download astm c1107 pdf 30 products find and drained and essentially free of hardened mortar and other foreign material that can be removed with a trowel or by reasonably striking with a hammer. Range 50 degrees to 90 degrees f, application time 30 min. Astm c1107c1107m14 standard specification for packaged dry, hydrauliccement grout nonshrink2014. Find the most uptodate version of astm c1107c1107m at engineering360. Astm c1107c1107m17 standard specification for packaged dry, hydrauliccement grout nonshrink standard by astm international, 12012017. Designer choices and responsibilities in astm c1063 and. Active standard astm c1107 c1107m developed by subcommittee.

Sc multipurpose grout is a product in the nonmetallic grout category that meets astm c1107, crd. Find the most uptodate version of astm c1107 at engineering360. Astm c1107c1107m14a packaged dry, hydrauliccement grout nonshrink. Astm c1107c1107m14 standard specification for packaged. Standard specification for packaged dry, hydraulic cement grout nonshrink. Range 50 degrees to 90 degrees f, application temp. C109c109m test method for compressive strength of hydraulic cement mortars using 2in. Due to this revision, a precision nonshrink grout can no longer be specified using this test method. The data shown above reflects typical results based on laboratory testing under controlled conditions.